Refrigeration & Transport Expansion Valves (FWE, FFE, JBE)

Fujikoki F series · J series

Refrigeration & Transport Expansion Valves

Our product range includes expansion valves for buses and refrigerated trucks. FWE, FFE and JBE are flare-connection thermostatic expansion valves that can also be used in hot gas defrost cycles.

Fujikoki FWE thermostatic expansion valve
F series · Flare

FWE Thermostatic Expansion Valve

Capacity
0.35–17.6 kW
Pipe sizes
3 sizes, 6.35–15.88 mm
Refrigerants
R134a, R407C, R404A, R410A
Fujikoki FFE thermostatic expansion valve
F series · Flare · Build-to-order

FFE Thermostatic Expansion Valve

Capacity
1.1–17.6 kW
Pipe sizes
2 sizes, 6.35–12.70 mm
Refrigerants
R134a, R407C, R404A, R410A
Fujikoki JBE thermostatic expansion valve
J series · Flare

JBE Thermostatic Expansion Valve

Capacity
10.6–105.5 kW
Pipe sizes
3 sizes, 9.52–19.05 mm
Refrigerants
R134a, R407C, R404A, R410A

Compare

TypeCapacityPipe inlet × outletEqualizationMax. working pressureWeightNote
FWE0.35–17.6 kW6.35 (1/4) × 12.70 (1/2)
9.52 (3/8) × 12.70 (1/2)
12.70 (1/2) × 15.88 (5/8)
Internal / External1.47 MPaG
(R134a / R407C / R404A)
330 / 340 gFlare · 3 pipe sizes
FFE1.1–17.6 kW6.35 (1/4) × 12.70 (1/2)
9.52 (3/8) × 12.70 (1/2)
Internal / External1.47 MPaG
(R134a / R407C / R404A)
290 / 300 gCompact · build-to-order
JBE10.6–105.5 kW9.52 (3/8) × 12.70 (1/2)
12.70 (1/2) × 15.88 (5/8)
15.88 (5/8) × 19.05 (3/4)
External2.75 MPaG
(R134a / R407C / R404A)
540 / 850 gMedium capacity · ø44 / ø60 diaphragm

Internal equalization JBE models are available only on a build-to-order basis.

Evaporating temperature range

Same ranges for FWE, FFE and JBE. The last letter of the model number selects the range.

RefrigerantWide (W)Medium temperature (M)Low temperature (L)
R134a10°C to -30°C-1°C to -30°C-18°C to -30°C
R407C10°C to -40°C-1°C to -40°C-18°C to -40°C
R404A10°C to -45°C-1°C to -45°C-18°C to -45°C
R410A10°C to -45°C——

How to read the model number

Models of the F series are displayed as shown below (example: FWE-E1534QW).

FWEType
EExternal equalization
15Capacity
34Pipe code
QRefrigerant
WEvap. range
Equalizing systemE is appended for external equalization.
Refrigerant codeR134a: Q · R22/R407C: H · R404A: N · R410A: G
Evaporating temperature rangeWide use: W · Medium temperature use: M · Low temperature use: L
Capacity & pipe codeRead them from the model list (for example “1534” = 5.3 kW, 9.52 × 12.70 mm).

Specifications: FUJIKOKI Product Catalog (2016), pages 7, 9 and 13–14.